Working pressure | Pressure regulator | Safety set up | Body material | Actuation | Inlet | Outlet | Max flow range | Dip tube | Gauges | Guards | Gas | |
C81 | 8 | PR | 3-5 | L | OC | 25E | 239 | 100 | 0 | 0 | - | He |
Valve with integrated pressure regulator - Balloon valves - C817/C818
The C817/C818 are helium balloon valves for 200 or 300 Bar cylinders. The VIPR (valve with integrated pressure regulator) all-in-one solution combines space saving, transportability, safety and faster latex or foil balloons inflation.
Key advantages
- Brass valve with integrated pressure regulator for Helium service
- Separated filling port
- Specific outlet nozzle
- If non-return valve on filling part, specific filling adaptor recommended
- Fixed outlet pressure and flow
- Permanent gas tight seal
- π marking according TPED directive
- Tested according EN ISO 10297 and CGA V9 standards
Specifications
Working pressure pmax. | 300 bar |
Gas type | He |
Helium leak rate at pmax. | Internal 10-3 mbarl/sec External 10-3 mbarl/sec |
Flow | 100-110l/mn |
Temperature range | -20 to +65 °c |
Material | Handwheel: aluminium Seat: PA 6.6 O-rings: EPDM Body: brass |
In- and outlet connections | In accordance with all country standards |