Print
Bellows high pressure valve for HP, UHP, cryogenic gases and fluids – HP9000
HP9000 is a stop globe valve with replaceable bellows sealing. The valve is dedicated to high pressure at cryogenic temperature and can be actuated by a manual handwheel or a pneumatic actuator. It is ideally suited for liquid nitrogen and liquid oxygen, vacuum, pure and ultra pure gases or liquids, combustible gases or liquids, oxidizings gases or liquids, toxic and corrosive gases or liquids, radioactive gases or liquids, noble gases or liquids.
Key advantages
  • 100% Helium leak test performed on all valve
  • Sustainable metallic bellows providing a high internal/ external tightness
  • Fluid specific seat material as standard options: Metal - Metal on request
  • Visual Open-Close indicator for both manual and pneumatic versions
  • Individual serial number for full traceability
  • Corrosion resistant internal option available: Hastelloy® bellows
  • Electropolished surface roughness
  • 100% degreased for Oxygen use
  • Cryogenic extension

CONSTRUCTION MATERIAL

  Parts Material
Wetted parts Body SS 316L
Seat PCTFE or Vespel
Bellows SS 316L
Head/body seal gasket UNS N02201 (Nickel)
Non-wetted parts Handwheel Anodized aluminium
Actuator Body SS 316L and Painted
anodized aluminium
Others SS 430F and C38500

SURFACE FINISH

- EP4 EP2
Ra 0.8 μm Ra 0.4 μm EP  Ra 0.25 μm EP 

SEAT DIAMETER / FLOW CAPACITY

Valve Seat diameter Flow capacity
(Cv)
HP9008-N 8mm 1,2
HP9012-N 12mm 2,15
HP9008-C 8mm 0,77
HP9012-C 12mm 1,91

Other dimensions upon request

All specifications subject to change without notice.

MANUAL DIMENSIONS

MAN. HP9008 MI  HP9012 MI
C 49mm/(1.93") 49mm/(1.93") 
O 52mm/(2.05") 53mm/(2.09") 
ØB 70mm/(2.76") 70mm/(2.76")
ØE (up to) 22.5mm/(0.89") 31.5mm/(1.24") 
ØV 100mm/(3.94") 100mm/(3.94")
He 290.5mm/(11.44") 290.5mm/(11.44")
L 90mm/(3.54") 140mm/(5.51")
N 45mm/(1.77") 70mm/(2.76")

PNEUMATIC DIMENSIONS

PNEU. HP9008 NC/NO HP9012 NC/NO
C 32mm/(1.26") 32mm/(1.26")
O 35mm/(1.38") 36mm/(1.42")
ØB 70mm/(2.76")  70mm/(2.76") 
ØE (up to) 22.5mm/(0.89") 31.5mm/(1.24")
ØV 100mm/(3.94") 100mm/(3.94")
He 376.5mm/(14.82") 402,5mm/(15.84")
L 90mm/(3.54") 140mm/(5.51") 
N 45mm/(1.77") 70mm/(2.76") 

Dimensions are for reference only and are subject to change without notice

Specifications
Fluid mediaStandard, high and ultra high purity and corrosive gases or liquids
Max. working pressure24 MPa (240 bar)*
Pneumatic actuator operating pressure0.5 - 0.7 MPa (5 - 7 bar)
Temperature range77.15 K to 523.15 K (-196°C to +250°C)*
Flow capacity (cv)see table below
Nominal seat diametersee table below
Certified max. helium outboard leak rate (at max. pressure)≤ 1.10-10 Pa.m3 .s-1
Certified max. helium across the seat leak rate (at max. pressure)≤ 3.10-10 Pa.m3 .s-1
Dimensional drawings
DrawingDrawing
Product Configurator
 
Size
type
Actuation
Body material
Seat material
End-connection (1)
Surface finish
Options (2)
HP90
08
-C
MI
I
/K
BWO
-
-
 
Seat Ø8mm
08
Seat Ø12mm
12
For oxidizing gases(3)
-C
For non oxidizing gases
-N
Manual
MI
Pneumatic normally open
NO
Pneumatic normally closed
NC
SS316L
I
PCTFE
/K
PI (Vespel®)
/V
Butt welded orbital
BWO
Butt welded
BW
Metal face seal - Male
MV
Metal face seal - Female
FV
Ra 0.8µm
-
Ra 0.4µm (electropolished)
EP4
Ra 0.25µm (electropolished)
EP2
No option
-
Bottom support
FP
Actuator vent for H2
H2
Solenoid valve
EV
Double limit switches
MRE2
Proximity sensors (ATEX)
DPI2
Purge port (1)
PGP
(1) Size to be defined by customer and ROTAREX
(2) Combinable
(3) Max. working pressure for O2 200 bar
Downloadable catalogs, brochures
  • Download
    Line Valves for UHP, Speciality and Cryogenic gases and fluids
    Last update: Jan 25, 2023
    Available in: en/FR/CN/KR
Connect with an Expert
×
Loading

This site uses cookies.

Rotarex uses cookies to ensure a better and easier online experience. Please click here to accept the continued use of these cookies after reading our revised COOKIES POLICY.

Please note, you may continue to use the website even if you do not accept the use of cookies. However, the visitor experience on subsequent visits will be diminished.

Read the full COOKIES POLICY.

Refuse all non essential cookies